ACECO
SC-1
Condition:
Pre-Owned - Used Twice
Tested:
Fully Operational
Appearance:
New
Warranty:
Fully Tested But Sold As Is
Instructions:
Printed Instructions Included
Cost:
$139 + $9.50 Shipping & Insurance
Restrictions:
Will Ship To U.S. Only
ACECO
SC-1
The
Aceco SC-1 hand-held radio frequency counter is compact,
truly
pocket-sized,
versatile test instrument designed for measuring any
digital,
on/off
keying or analog signal on frequencies between 30 MHz
and 2.8
GHz.
Supplied as a complete with internal NiCd pack, AC wall
charger
and
7 section telescopic antenna.
Specifications
- 50
Ohms (BNC Socket) VSWR less than 2:1
- 30
MHz - 2.8 GHz
- less
than 5 mV
- 15
dBm
- 10
KHz for digital signals or On/Off Keying &
- 1
KHz for Analog Signals
- Less
than 1 PPM at room temperature
- 210
g
- 80
mm high x 68 mm wide x 31 mm deep
- Stamped
aluminum with black anodized finish
- Internal
4 x AA 600 mAH NiCd pack
- 9
VDC 300 mA
Features
*
7 digit Liquid Crystal Display
*
Frequency counter for digital, on/off keying and analog
signals with a minimum
pulse
width of 250 uS.
*
Ultra sensitive synchronous detector - 16 section bargraph
to show RF signal
strength
(-35dBm to 0dBm)
*
Two range positions - the 1 GHz position for frequencies
between 30 MHz and 0.8 GHz and the 2.8 GHz position
for frequencies between 500 MHz and 2.8 GHz.
*
Squelch adjustment for input signals
*
Hold switch to lock display
*
Low battery indicator
*
Low power consumption (Average 5 hour battery life)
Controls
1.
SQL Knob - This knob turns the RF counter on and tunes
the squelch
up
or down to set the signal strength for reception.
2.
Range Switch - This should be switched to the 1 GHz
position for
frequencies
between 30 MHz and 0.8 GHz and switched to the 2.8
GHz
position for frequencies between 500 MHz and 2.8 GHz.
3.
Hold Button - This holds the current display and stops
the counter
from
counting.
4.
Calibration - The calibration adjustment opening is
located on the
front
panel of the counter. This allows access to the trimmer
capacitor
that provides about a 10 PPM adjustment range of the
time
base oscillator. This is not usually necessary but to
do so read
a
signal of a known frequency before adjusting the trimmer
for
correct
frequency display. If you calibrate at 4.1943 MHz or
above
then
the counter will be more accurate.
Aceco
SC-1 On The Web
Disclosure
& Disclaimer
Information
on the ACSS marketplace is listed without any warranties
whatsoever. Buyer alone is responsible to ensure that
products listed herein are as described. Buyer agrees to hold
harmless ACSS, its Board of Directors and its management
from any and all claims that may arise from use of the
listing information
and/or from the purchase of any products listed on
this site. Buyers and sellers alone are responsible
for determining the status regarding the legal transfer of TSCM
equipment and instrumentation within and outside the United States.
|